Functional Block: K

Types Reference: Shared types referenced below are defined in OCPP-2.0.1-DataTypes.md.
Types used only within this block are documented inline below.

#Messages


#GetLog

Direction: CSMS → CS

#GetLogRequest

Field Type Required Constraints Description
log LogParametersType Yes
logType LogEnumType Yes
requestId integer Yes The Id of this request
retries integer No This specifies how many times the Charging Station must try to upload the log before giving up. If this field is not present, it is left to Charging Station to decide how many times it wants to retry.
retryInterval integer No The interval in seconds after which a retry may be attempted. If this field is not present, it is left to Charging Station to decide how long to wait between attempts.
customData CustomDataType No
Example GetLogRequest
{
  "log": {
    "remoteLocation": "string"
  },
  "logType": "DiagnosticsLog",
  "requestId": 0
}

#GetLogResponse

Field Type Required Constraints Description
status LogStatusEnumType Yes
filename string No maxLength: 255 This contains the name of the log file that will be uploaded. This field is not present when no logging information is available.
statusInfo StatusInfoType No
customData CustomDataType No

#LogStatusNotification

Direction: CS → CSMS

#LogStatusNotificationRequest

Field Type Required Constraints Description
status UploadLogStatusEnumType Yes
requestId integer No The request id that was provided in GetLogRequest that started this log upload. This field is mandatory, unless the message was triggered by a TriggerMessageRequest AND there is no log upload ongoing.
customData CustomDataType No
Example LogStatusNotificationRequest
{
  "status": "BadMessage"
}

#LogStatusNotificationResponse

No required fields. An empty {} is a valid response.


#NotifyEvent

Direction: CS → CSMS

#NotifyEventRequest

Field Type Required Constraints Description
eventData EventDataType[] Yes minItems: 1
generatedAt string (date-time) Yes Timestamp of the moment this message was generated at the Charging Station.
seqNo integer Yes Sequence number of this message. First message starts at 0.
tbc boolean No “to be continued” indicator. Indicates whether another part of the report follows in an upcoming notifyEventRequest message. Default value when omitted is false. Default: False
customData CustomDataType No
Example NotifyEventRequest
{
  "eventData": [
    {
      "eventId": 0,
      "timestamp": "2024-01-15T10:30:00Z",
      "trigger": "Alerting",
      "actualValue": "string",
      "eventNotificationType": "HardWiredNotification",
      "component": "{...}",
      "variable": "{...}"
    }
  ],
  "generatedAt": "2024-01-15T10:30:00Z",
  "seqNo": 0
}

#NotifyEventResponse

No required fields. An empty {} is a valid response.


#SetMonitoringBase

Direction: CSMS → CS

#SetMonitoringBaseRequest

Field Type Required Constraints Description
monitoringBase MonitoringBaseEnumType Yes
customData CustomDataType No
Example SetMonitoringBaseRequest
{
  "monitoringBase": "All"
}

#SetMonitoringBaseResponse

Field Type Required Constraints Description
status GenericDeviceModelStatusEnumType Yes
statusInfo StatusInfoType No
customData CustomDataType No

#SetVariableMonitoring

Direction: CSMS → CS

#SetVariableMonitoringRequest

Field Type Required Constraints Description
setMonitoringData SetMonitoringDataType[] Yes minItems: 1
customData CustomDataType No
Example SetVariableMonitoringRequest
{
  "setMonitoringData": [
    {
      "value": 0.0,
      "type": "UpperThreshold",
      "severity": 0,
      "component": "{...}",
      "variable": "{...}"
    }
  ]
}

#SetVariableMonitoringResponse

Field Type Required Constraints Description
setMonitoringResult SetMonitoringResultType[] Yes minItems: 1
customData CustomDataType No

#SetMonitoringLevel

Direction: CSMS → CS

#SetMonitoringLevelRequest

Field Type Required Constraints Description
severity integer Yes The Charging Station SHALL only report events with a severity number lower than or equal to this severity. The severity range is 0-9, with 0 as the highest and 9 as the lowest severity level. The severity levels have the following meaning: + 0-Danger + Indicates lives are potentially in danger. Urgent attention is needed and action should be taken immediately. + 1-Hardware Failure + Indicates that the Charging Station is unable to continue regular operations due to Hardware issues. Action is required. + 2-System Failure + Indicates that the Charging Station is unable to continue regular operations due to software or minor hardware issues. Action is required. + 3-Critical + Indicates a critical error. Action is required. + 4-Error + Indicates a non-urgent error. Action is required. + 5-Alert + Indicates an alert event. Default severity for any type of monitoring event. + 6-Warning + Indicates a warning event. Action may be required. + 7-Notice + Indicates an unusual event. No immediate action is required. + 8-Informational + Indicates a regular operational event. May be used for reporting, measuring throughput, etc. No action is required. + 9-Debug + Indicates information useful to developers for debugging, not useful during operations.
customData CustomDataType No
Example SetMonitoringLevelRequest
{
  "severity": 0
}

#SetMonitoringLevelResponse

Field Type Required Constraints Description
status GenericStatusEnumType Yes
statusInfo StatusInfoType No
customData CustomDataType No

#GetMonitoringReport

Direction: CSMS → CS

#GetMonitoringReportRequest

Field Type Required Constraints Description
requestId integer Yes The Id of the request.
componentVariable ComponentVariableType[] No minItems: 1
monitoringCriteria MonitoringCriterionEnumType[] No minItems: 1, maxItems: 3 This field contains criteria for components for which a monitoring report is requested
customData CustomDataType No
Example GetMonitoringReportRequest
{
  "requestId": 0
}

#GetMonitoringReportResponse

Field Type Required Constraints Description
status GenericDeviceModelStatusEnumType Yes
statusInfo StatusInfoType No
customData CustomDataType No

#ClearVariableMonitoring

Direction: CSMS → CS

#ClearVariableMonitoringRequest

Field Type Required Constraints Description
id integer[] Yes minItems: 1 List of the monitors to be cleared, identified by there Id.
customData CustomDataType No
Example ClearVariableMonitoringRequest
{
  "id": [
    0
  ]
}

#ClearVariableMonitoringResponse

Field Type Required Constraints Description
clearMonitoringResult ClearMonitoringResultType[] Yes minItems: 1
customData CustomDataType No

#NotifyMonitoringReport

Direction: CS → CSMS

#NotifyMonitoringReportRequest

Field Type Required Constraints Description
generatedAt string (date-time) Yes Timestamp of the moment this message was generated at the Charging Station.
requestId integer Yes The id of the GetMonitoringRequest that requested this report.
seqNo integer Yes Sequence number of this message. First message starts at 0.
monitor MonitoringDataType[] No minItems: 1
tbc boolean No “to be continued” indicator. Indicates whether another part of the monitoringData follows in an upcoming notifyMonitoringReportRequest message. Default value when omitted is false. Default: False
customData CustomDataType No
Example NotifyMonitoringReportRequest
{
  "generatedAt": "2024-01-15T10:30:00Z",
  "requestId": 0,
  "seqNo": 0
}

#NotifyMonitoringReportResponse

No required fields. An empty {} is a valid response.


#CustomerInformation

Direction: CSMS → CS

#CustomerInformationRequest

Field Type Required Constraints Description
clear boolean Yes Flag indicating whether the Charging Station should clear all information about the customer referred to.
report boolean Yes Flag indicating whether the Charging Station should return NotifyCustomerInformationRequest messages containing information about the customer referred to.
requestId integer Yes The Id of the request.
customerCertificate CertificateHashDataType No
customerIdentifier string No maxLength: 64 A (e.g. vendor specific) identifier of the customer this request refers to. This field contains a custom identifier other than IdToken and Certificate. One of the possible identifiers (customerIdentifier, customerIdToken or customerCertificate) should be in the request message.
idToken IdTokenType No
customData CustomDataType No
Example CustomerInformationRequest
{
  "clear": false,
  "report": false,
  "requestId": 0
}

#CustomerInformationResponse

Field Type Required Constraints Description
status CustomerInformationStatusEnumType Yes
statusInfo StatusInfoType No
customData CustomDataType No

#NotifyCustomerInformation

Direction: CS → CSMS

#NotifyCustomerInformationRequest

Field Type Required Constraints Description
data string Yes maxLength: 512 (Part of) the requested data. No format specified in which the data is returned. Should be human readable.
generatedAt string (date-time) Yes Timestamp of the moment this message was generated at the Charging Station.
requestId integer Yes The Id of the request.
seqNo integer Yes Sequence number of this message. First message starts at 0.
tbc boolean No “to be continued” indicator. Indicates whether another part of the monitoringData follows in an upcoming notifyMonitoringReportRequest message. Default value when omitted is false. Default: False
customData CustomDataType No
Example NotifyCustomerInformationRequest
{
  "data": "string",
  "generatedAt": "2024-01-15T10:30:00Z",
  "requestId": 0,
  "seqNo": 0
}

#NotifyCustomerInformationResponse

No required fields. An empty {} is a valid response.


#Local Types

Types used only within this block's messages.

#ClearMonitoringStatusEnumType

Result of the clear request for this monitor, identified by its Id.

Value
Accepted
Rejected
NotFound

Used in: ClearVariableMonitoring


#CustomerInformationStatusEnumType

Indicates whether the request was accepted.

Value
Accepted
Rejected
Invalid

Used in: CustomerInformation


#EventNotificationEnumType

Specifies the event notification type of the message.

Value
HardWiredNotification
HardWiredMonitor
PreconfiguredMonitor
CustomMonitor

Used in: NotifyEvent


#EventTriggerEnumType

Type of monitor that triggered this event, e.g. exceeding a threshold value.

Value
Alerting
Delta
Periodic

Used in: NotifyEvent


#LogEnumType

This contains the type of log file that the Charging Station should send.

Value
DiagnosticsLog
SecurityLog

Used in: GetLog


#LogStatusEnumType

This field indicates whether the Charging Station was able to accept the request.

Value
Accepted
Rejected
AcceptedCanceled

Used in: GetLog


#MonitoringBaseEnumType

Specify which monitoring base will be set

Value
All
FactoryDefault
HardWiredOnly

Used in: SetMonitoringBase


#MonitoringCriterionEnumType

Value
ThresholdMonitoring
DeltaMonitoring
PeriodicMonitoring

Used in: GetMonitoringReport


#SetMonitoringStatusEnumType

Status is OK if a value could be returned. Otherwise this will indicate the reason why a value could not be returned.

Value
Accepted
UnknownComponent
UnknownVariable
UnsupportedMonitorType
Rejected
Duplicate

Used in: SetVariableMonitoring


#UploadLogStatusEnumType

This contains the status of the log upload.

Value
BadMessage
Idle
NotSupportedOperation
PermissionDenied
Uploaded
UploadFailure
Uploading
AcceptedCanceled

Used in: LogStatusNotification


#ClearMonitoringResultType

Field Type Required Constraints Description
id integer Yes Id of the monitor of which a clear was requested.
status ClearMonitoringStatusEnumType Yes
statusInfo StatusInfoType No
customData CustomDataType No

Used in: ClearVariableMonitoring


#ComponentVariableType

Class to report components, variables and variable attributes and characteristics.

Field Type Required Constraints Description
component ComponentType Yes
variable VariableType No
customData CustomDataType No

Used in: GetMonitoringReport, GetReport


#EventDataType

Class to report an event notification for a component-variable.

Field Type Required Constraints Description
actualValue string Yes maxLength: 2500 Actual value (attributeType Actual) of the variable. The Configuration Variable ReportingValueSize can be used to limit GetVariableResult.attributeValue, VariableAttribute.value and EventData.actualValue. The max size of these values will always remain equal.
component ComponentType Yes
eventId integer Yes Identifies the event. This field can be referred to as a cause by other events.
eventNotificationType EventNotificationEnumType Yes
timestamp string (date-time) Yes Timestamp of the moment the report was generated.
trigger EventTriggerEnumType Yes
variable VariableType Yes
cause integer No Refers to the Id of an event that is considered to be the cause for this event.
cleared boolean No Cleared is set to true to report the clearing of a monitored situation, i.e. a 'return to normal'.
techCode string No maxLength: 50 Technical (error) code as reported by component.
techInfo string No maxLength: 500 Technical detail information as reported by component.
transactionId string No maxLength: 36 If an event notification is linked to a specific transaction, this field can be used to specify its transactionId.
variableMonitoringId integer No Identifies the VariableMonitoring which triggered the event.
customData CustomDataType No

Used in: NotifyEvent


#LogParametersType

Generic class for the configuration of logging entries.

Field Type Required Constraints Description
remoteLocation string Yes maxLength: 512 The URL of the location at the remote system where the log should be stored.
latestTimestamp string (date-time) No This contains the date and time of the latest logging information to include in the diagnostics.
oldestTimestamp string (date-time) No This contains the date and time of the oldest logging information to include in the diagnostics.
customData CustomDataType No

Used in: GetLog


#MonitoringDataType

Class to hold parameters of SetVariableMonitoring request.

Field Type Required Constraints Description
component ComponentType Yes
variable VariableType Yes
variableMonitoring VariableMonitoringType[] Yes minItems: 1
customData CustomDataType No

Used in: NotifyMonitoringReport


#SetMonitoringDataType

Class to hold parameters of SetVariableMonitoring request.

Field Type Required Constraints Description
component ComponentType Yes
severity integer Yes The severity that will be assigned to an event that is triggered by this monitor. The severity range is 0-9, with 0 as the highest and 9 as the lowest severity level. The severity levels have the following meaning: + 0-Danger + Indicates lives are potentially in danger. Urgent attention is needed and action should be taken immediately. + 1-Hardware Failure + Indicates that the Charging Station is unable to continue regular operations due to Hardware issues. Action is required. + 2-System Failure + Indicates that the Charging Station is unable to continue regular operations due to software or minor hardware issues. Action is required. + 3-Critical + Indicates a critical error. Action is required. + 4-Error + Indicates a non-urgent error. Action is required. + 5-Alert + Indicates an alert event. Default severity for any type of monitoring event. + 6-Warning + Indicates a warning event. Action may be required. + 7-Notice + Indicates an unusual event. No immediate action is required. + 8-Informational + Indicates a regular operational event. May be used for reporting, measuring throughput, etc. No action is required. + 9-Debug + Indicates information useful to developers for debugging, not useful during operations.
type MonitorEnumType Yes
value number Yes Value for threshold or delta monitoring. For Periodic or PeriodicClockAligned this is the interval in seconds.
variable VariableType Yes
id integer No An id SHALL only be given to replace an existing monitor. The Charging Station handles the generation of id's for new monitors.
transaction boolean No Monitor only active when a transaction is ongoing on a component relevant to this transaction. Default = false. Default: False
customData CustomDataType No

Used in: SetVariableMonitoring


#SetMonitoringResultType

Class to hold result of SetVariableMonitoring request.

Field Type Required Constraints Description
component ComponentType Yes
severity integer Yes The severity that will be assigned to an event that is triggered by this monitor. The severity range is 0-9, with 0 as the highest and 9 as the lowest severity level. The severity levels have the following meaning: + 0-Danger + Indicates lives are potentially in danger. Urgent attention is needed and action should be taken immediately. + 1-Hardware Failure + Indicates that the Charging Station is unable to continue regular operations due to Hardware issues. Action is required. + 2-System Failure + Indicates that the Charging Station is unable to continue regular operations due to software or minor hardware issues. Action is required. + 3-Critical + Indicates a critical error. Action is required. + 4-Error + Indicates a non-urgent error. Action is required. + 5-Alert + Indicates an alert event. Default severity for any type of monitoring event. + 6-Warning + Indicates a warning event. Action may be required. + 7-Notice + Indicates an unusual event. No immediate action is required. + 8-Informational + Indicates a regular operational event. May be used for reporting, measuring throughput, etc. No action is required. + 9-Debug + Indicates information useful to developers for debugging, not useful during operations.
status SetMonitoringStatusEnumType Yes
type MonitorEnumType Yes
variable VariableType Yes
id integer No Id given to the VariableMonitor by the Charging Station. The Id is only returned when status is accepted. Installed VariableMonitors should have unique id's but the id's of removed Installed monitors should have unique id's but the id's of removed monitors MAY be reused.
statusInfo StatusInfoType No
customData CustomDataType No

Used in: SetVariableMonitoring


#VariableMonitoringType

A monitoring setting for a variable.

Field Type Required Constraints Description
id integer Yes Identifies the monitor.
severity integer Yes The severity that will be assigned to an event that is triggered by this monitor. The severity range is 0-9, with 0 as the highest and 9 as the lowest severity level. The severity levels have the following meaning: + 0-Danger + Indicates lives are potentially in danger. Urgent attention is needed and action should be taken immediately. + 1-Hardware Failure + Indicates that the Charging Station is unable to continue regular operations due to Hardware issues. Action is required. + 2-System Failure + Indicates that the Charging Station is unable to continue regular operations due to software or minor hardware issues. Action is required. + 3-Critical + Indicates a critical error. Action is required. + 4-Error + Indicates a non-urgent error. Action is required. + 5-Alert + Indicates an alert event. Default severity for any type of monitoring event. + 6-Warning + Indicates a warning event. Action may be required. + 7-Notice + Indicates an unusual event. No immediate action is required. + 8-Informational + Indicates a regular operational event. May be used for reporting, measuring throughput, etc. No action is required. + 9-Debug + Indicates information useful to developers for debugging, not useful during operations.
transaction boolean Yes Monitor only active when a transaction is ongoing on a component relevant to this transaction.
type MonitorEnumType Yes
value number Yes Value for threshold or delta monitoring. For Periodic or PeriodicClockAligned this is the interval in seconds.
customData CustomDataType No

Used in: NotifyMonitoringReport