Examples

DC Site Power Limit
Cap the entire Charging Station to 150 kW (ChargingStationMaxProfile)
Grid Operator Constraint
External grid limits: 100 kW off-peak, 50 kW midday (ChargingStationExternalConstraints)
Off-Peak AC
Daily recurring: 32A at night, 16A during peak hours (TxDefaultProfile)
DC Ramp Down
Start at 150 kW, step down to 50 kW after 20 min (TxProfile, Relative)
Emergency Curtailment
Stop all charging immediately with a high-priority override (stackLevel 99, limit 0)
Dual-Schedule Profile
Two schedules on one profile: one in Amps, one in Watts (multi-schedule feature)

* Required field

Target

0 = entire Charging Station, 1+ = specific EVSE

Profile

Unique identifier for this charging profile
Higher levels override lower. Same level + purpose = replacement

Conditional & Optional Fields

Profile is not active before this time
Profile expires after this time

Charging Schedules

OCPP 2.0.1 allows 1–3 schedules per profile. Each schedule can use a different rate unit.