Functional Block: J

Types Reference: Shared types referenced below are defined in OCPP-2.1-DataTypes.md.
Types used only within this block are documented inline below.

#Messages


#MeterValues

Direction: CS → CSMS

#MeterValuesRequest

Field Type Required Constraints Description
evseId integer Yes min: 0.0 This contains a number (>0) designating an EVSE of the Charging Station. ‘0’ (zero) is used to designate the main power meter.
meterValue MeterValueType[] Yes minItems: 1
customData CustomDataType No
Example MeterValuesRequest
{
  "evseId": 0,
  "meterValue": [
    {
      "timestamp": "2024-01-15T10:30:00Z",
      "sampledValue": [
        "{...}"
      ]
    }
  ]
}

#MeterValuesResponse

No required fields. An empty {} is a valid response.


#Local Types

Types used only within this block's messages.

#LocationEnumType

Indicates where the measured value has been sampled. Default = "Outlet"

Default: Outlet

Value
Body
Cable
EV
Inlet
Outlet
Upstream

Used in: MeterValues, TransactionEvent


#MeasurandEnumType

Type of measurement. Default = "Energy.Active.Import.Register"

Default: Energy.Active.Import.Register

Value
Current.Export
Current.Export.Offered
Current.Export.Minimum
Current.Import
Current.Import.Offered
Current.Import.Minimum
Current.Offered
Display.PresentSOC
Display.MinimumSOC
Display.TargetSOC
Display.MaximumSOC
Display.RemainingTimeToMinimumSOC
Display.RemainingTimeToTargetSOC
Display.RemainingTimeToMaximumSOC
Display.ChargingComplete
Display.BatteryEnergyCapacity
Display.InletHot
Energy.Active.Export.Interval
Energy.Active.Export.Register
Energy.Active.Import.Interval
Energy.Active.Import.Register
Energy.Active.Import.CableLoss
Energy.Active.Import.LocalGeneration.Register
Energy.Active.Net
Energy.Active.Setpoint.Interval
Energy.Apparent.Export
Energy.Apparent.Import
Energy.Apparent.Net
Energy.Reactive.Export.Interval
Energy.Reactive.Export.Register
Energy.Reactive.Import.Interval
Energy.Reactive.Import.Register
Energy.Reactive.Net
EnergyRequest.Target
EnergyRequest.Minimum
EnergyRequest.Maximum
EnergyRequest.Minimum.V2X
EnergyRequest.Maximum.V2X
EnergyRequest.Bulk
Frequency
Power.Active.Export
Power.Active.Import
Power.Active.Setpoint
Power.Active.Residual
Power.Export.Minimum
Power.Export.Offered
Power.Factor
Power.Import.Offered
Power.Import.Minimum
Power.Offered
Power.Reactive.Export
Power.Reactive.Import
SoC
Voltage
Voltage.Minimum
Voltage.Maximum

Used in: MeterValues, TransactionEvent


#PhaseEnumType

Indicates how the measured value is to be interpreted. For instance between L1 and neutral (L1-N) Please note that not all values of phase are applicable to all Measurands. When phase is absent, the measured value is interpreted as an overall value.

Value
L1
L2
L3
N
L1-N
L2-N
L3-N
L1-L2
L2-L3
L3-L1

Used in: MeterValues, TransactionEvent


#ReadingContextEnumType

Type of detail value: start, end or sample. Default = "Sample.Periodic"

Default: Sample.Periodic

Value
Interruption.Begin
Interruption.End
Other
Sample.Clock
Sample.Periodic
Transaction.Begin
Transaction.End
Trigger

Used in: MeterValues, TransactionEvent


#MeterValueType

Collection of one or more sampled values in MeterValuesRequest and TransactionEvent. All sampled values in a MeterValue are sampled at the same point in time.

Field Type Required Constraints Description
sampledValue SampledValueType[] Yes minItems: 1
timestamp string (date-time) Yes Timestamp for measured value(s).
customData CustomDataType No

Used in: MeterValues, TransactionEvent


#SampledValueType

Single sampled value in MeterValues. Each value can be accompanied by optional fields. To save on mobile data usage, default values of all of the optional fields are such that. The value without any additional fields will be interpreted, as a register reading of active import energy in Wh (Watt-hour) units.

Field Type Required Constraints Description
value number Yes Indicates the measured value.
context ReadingContextEnumType No
location LocationEnumType No
measurand MeasurandEnumType No
phase PhaseEnumType No
signedMeterValue SignedMeterValueType No
unitOfMeasure UnitOfMeasureType No
customData CustomDataType No

Used in: MeterValues, TransactionEvent


#SignedMeterValueType

Represent a signed version of the meter value.

Field Type Required Constraints Description
encodingMethod string Yes maxLength: 50 Format used by the energy meter to encode the meter data. For example: OCMF or EDL.
signedMeterData string Yes maxLength: 32768 Base64 encoded, contains the signed data from the meter in the format specified in encodingMethod, which might contain more then just the meter value. It can contain information like timestamps, reference to a customer etc.
publicKey string No maxLength: 2500 (2.1) Base64 encoded, sending depends on configuration variable PublicKeyWithSignedMeterValue.
signingMethod string No maxLength: 50 (2.1) Method used to create the digital signature. Optional, if already included in signedMeterData. Standard values for this are defined in Appendix as SigningMethodEnumStringType.
customData CustomDataType No

Used in: MeterValues, TransactionEvent


#UnitOfMeasureType

Represents a UnitOfMeasure with a multiplier

Field Type Required Constraints Description
multiplier integer No Multiplier, this value represents the exponent to base 10. I.e. multiplier 3 means 10 raised to the 3rd power. Default is 0. + The multiplier only multiplies the value of the measurand. It does not specify a conversion between units, for example, kW and W. Default: 0
unit string No maxLength: 20 Unit of the value. Default = "Wh" if the (default) measurand is an "Energy" type. This field SHALL use a value from the list Standardized Units of Measurements in Part 2 Appendices. If an applicable unit is available in that list, otherwise a "custom" unit might be used. Default: Wh
customData CustomDataType No

Used in: MeterValues, TransactionEvent